Forte Software Ideas
Add a new idea
Log in / Sign up
Identify yourself with your email address
Email address
Recent
Trending
Popular
7
Vote
Allow files to be merged together
I go to 'File Manager', then I create a new file named TESTING-123 for floor beams. A couple days later I forgot I made that file so I create a new file called TESTING-123 then added roof beams, now there are 2 files for the same project with the ...
Created 13 Aug 12:17
5
Vote
Add A36 steel
Helpful when working on existing buildings to check effects on existing older structures when remodeling.
Created 08 Feb 15:26
1
Vote
Option to Mirror Beam
It would be nice to have a button that would mirror the beam.
Created 05 Feb 18:03
1
Vote
Slenderness Ratio up to 75
The NDS limits the slenderness ratio to 50 and up to 75 during construction. Adding an option to check construction slenderness ratios and subsequently running the axial compression and bending calculations would be helpful for reviewing different...
Created 30 Jan 23:57
2
Vote
Ability to see the different connector capacities
It would be great to see the design values for the hangers next to the hanger that is selected. It is a bit of a black box when it shows the different types of hangers that can be used.
Created 15 Apr 19:44
4
Vote
Add multi-plies standing post option
It would be great to add the option of multi-plies for the standing post element. Example: 2x4 SPF No1/No2 with 1, 2, 3 or 4 plies. Actually only can select 1 plie.
Created 18 Sep 19:57
2
Vote
Ability to modify the Calc Package summary to create a schedule
Can the first page be changed to create a schedule including the member size, required trimmer studs, and hangers so engineers can simply cut and paste the schedule and add to framing plans? Something like the attached. Currently we have to create...
Created 10 Apr 21:43
6
Vote
Diagrams and reaction values in results
Hi, It would be very useful to have detailed diagrams and values of reactions in the results. For example we can now only see governing factored reaction for the member. But when we need to take these reactions and transfer them below we need both...
Created 28 Jan 15:23
3
Vote
Reformat Member Report Printout
Report tab looks good, however, on the printout, none of the grids align and there is a lot of wasted space. Additionally, why is 8.5" x 11" the standard printout size in a world of PDFs we should have different sizes
Created 18 Jun 20:32
1
Vote
Rafter Heel Height at Bearing
Check minimum heel height
Created 21 Jan 20:01
« First
‹ Prev
…
8
9
10
11
12
13
14
15
16
…
Next ›
Last »